!-Generator IDFEditor 1.48 !-Option OriginalOrderTop UseSpecialFormat !-NOTE: All comments with '!-' are ignored by the IDFEditor and are generated automatically. !- Use '!' comments if they need to be retained when using the IDFEditor. Schedule:Constant,OutWaterTemp_valencia,Any Number,15; Schedule:Constant,OutWaterTemp_madrid,Any Number,13; Schedule:Compact, horario_ACS, !- Name Any Number, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR: AllDays, !- Field 2 UNTIL: 1:00, 0, !- Field 4 UNTIL: 2:00, 0, !- Field 6 UNTIL: 3:00, 0, !- Field 8 UNTIL: 4:00, 0, !- Field 10 UNTIL: 5:00, 0, !- Field 12 UNTIL: 6:00, 0, !- Field 14 UNTIL: 7:00, 0, !- Field 16 UNTIL: 8:00, 0, !- Field 18 UNTIL: 9:00, 0, !- Field 20 UNTIL: 10:00, 0, !- Field 22 UNTIL: 11:00, 0, !- Field 24 UNTIL: 12:00, 0, !- Field 26 UNTIL: 13:00, 0, !- Field 28 UNTIL: 14:00, .2, !- Field 30 UNTIL: 15:00, 0, !- Field 32 UNTIL: 16:00, 0, !- Field 34 UNTIL: 17:00, 0, !- Field 36 UNTIL: 18:00, 0, !- Field 38 UNTIL: 19:00, 0, !- Field 40 UNTIL: 20:00, .2, !- Field 42 UNTIL: 21:00, .6, !- Field 44 UNTIL: 22:00, 0, !- Field 46 UNTIL: 23:00, 0, !- Field 48 UNTIL: 24:00, 0; !- Field 50 WaterUse:Equipment, demanda_acs, !- Name General, !- End-Use Subcategory 0.0000311, !- Peak Flow Rate {m3/s} horario_ACS, !- Flow Rate Fraction Schedule Name Sinks and Showers Temp Schedule; !- Target Temperature Schedule Name ShadowCalculation, 365, !- Calculation Method 15000; !- Calculation Frequency WaterHeater:Mixed, Water Heater, !- Name 0.2, !- Tank Volume {m3} Hot Water Set Point Temp Schedule, !- Setpoint Temperature Schedule Name , !- Deadband Temperature Difference {deltaC} , !- Maximum Temperature Limit {C} Cycle, !- Heater Control Type 2000, !- Heater Maximum Capacity {W} , !- Heater Minimum Capacity {W} , !- Heater Ignition Minimum Flow Rate {m3/s} , !- Heater Ignition Delay {s} Electricity, !- Heater Fuel Type 1, !- Heater Thermal Efficiency , !- Part Load Factor Curve Name , !- Off Cycle Parasitic Fuel Consumption Rate {W} , !- Off Cycle Parasitic Fuel Type , !- Off Cycle Parasitic Heat Fraction to Tank , !- On Cycle Parasitic Fuel Consumption Rate {W} , !- On Cycle Parasitic Fuel Type , !- On Cycle Parasitic Heat Fraction to Tank Outdoors, !- Ambient Temperature Indicator , !- Ambient Temperature Schedule Name , !- Ambient Temperature Zone Name Outdoor_Air_Node, !- Ambient Temperature Outdoor Air Node Name 1, !- Off Cycle Loss Coefficient to Ambient Temperature {W/K} 1, !- Off Cycle Loss Fraction to Zone 1, !- On Cycle Loss Coefficient to Ambient Temperature {W/K} 1, !- On Cycle Loss Fraction to Zone , !- Peak Use Flow Rate {m3/s} , !- Use Flow Rate Fraction Schedule Name , !- Cold Water Supply Temperature Schedule Name Water Heater Use Inlet Node, !- Use Side Inlet Node Name Water Heater Use Outlet Node, !- Use Side Outlet Node Name 1, !- Use Side Effectiveness , !- Source Side Inlet Node Name , !- Source Side Outlet Node Name 1, !- Source Side Effectiveness autosize, !- Use Side Design Flow Rate {m3/s} autosize, !- Source Side Design Flow Rate {m3/s} 1.5; !- Indirect Water Heating Recovery Time {hr} OutdoorAir:Node, Outdoor_Air_Node, !- Name 1; !- Height Above Ground {m} SizingPeriod:WeatherFileDays, dia_cargas, !- Name 12, !- Begin Month 21, !- Begin Day of Month 12, !- End Month 21, !- End Day of Month Monday, !- Day of Week for Start Day Yes, !- Use Weather File Daylight Saving Period Yes; !- Use Weather File Rain and Snow Indicators Schedule:Constant,OutWaterTemp_bilbao,Any Number,13; ! WaterHeaterDHWPlantLoop.idf ! ! Basic file description: ! This input file illustrates WATER USE EQUIPMENT objects connected to a WATER HEATER:MIXED object in a simple ! plant loop for domestic hot water. ! ! Run: 2 design days. ! Building: None. ! System: None. ! Plant: Plant loop with one WATER HEATER:MIXED object connected to two WATER USE EQUIPMENT objects. Version,8.6; Building, Water Heater DHW Plant Loop Example, !- Name 0.0, !- North Axis {deg} Suburbs, !- Terrain 0.04, !- Loads Convergence Tolerance Value 0.04, !- Temperature Convergence Tolerance Value {deltaC} MinimalShadowing, !- Solar Distribution 25, !- Maximum Number of Warmup Days 6; !- Minimum Number of Warmup Days Timestep,1; GlobalGeometryRules, UpperLeftCorner, !- Starting Vertex Position CounterClockWise, !- Vertex Entry Direction Relative; !- Coordinate System RunPeriod, , !- Name 1, !- Begin Month 1, !- Begin Day of Month 12, !- End Month 31, !- End Day of Month Tuesday, !- Day of Week for Start Day Yes, !- Use Weather File Holidays and Special Days Yes, !- Use Weather File Daylight Saving Period No, !- Apply Weekend Holiday Rule Yes, !- Use Weather File Rain Indicators Yes; !- Use Weather File Snow Indicators SimulationControl, Yes, !- Do Zone Sizing Calculation Yes, !- Do System Sizing Calculation Yes, !- Do Plant Sizing Calculation Yes, !- Run Simulation for Sizing Periods Yes; !- Run Simulation for Weather File Run Periods Site:WaterMainsTemperature, Schedule, !- Calculation Method OutWaterTemp_madrid; !- Temperature Schedule Name ScheduleTypeLimits, Any Number; !- Name Schedule:Compact, Always On, !- Name Any Number, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR: AllDays, !- Field 2 UNTIL: 24:00, 1; !- Field 4 Schedule:Compact, Hot Water Set Point Temp Schedule, !- Name Any Number, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR: AllDays, !- Field 2 UNTIL: 24:00, 60; !- Field 4 Schedule:Compact, Sinks and Showers Temp Schedule, !- Name Any Number, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR: AllDays, !- Field 2 UNTIL: 24:00, 60; !- Field 4 !***PLANT DHW LOOP*** Sizing:Plant, DHW Loop, !- Plant or Condenser Loop Name HEATING, !- Loop Type 82., !- Design Loop Exit Temperature {C} 11; !- Loop Design Temperature Difference {deltaC} PlantLoop, DHW Loop, !- Name WATER, !- Fluid Type , !- User Defined Fluid Type DHW Loop Operation, !- Plant Equipment Operation Scheme Name Water Heater Use Loop Outlet Node, !- Loop Temperature Setpoint Node Name 100, !- Maximum Loop Temperature {C} 3, !- Minimum Loop Temperature {C} AUTOSIZE, !- Maximum Loop Flow Rate {m3/s} 0, !- Minimum Loop Flow Rate {m3/s} AUTOSIZE, !- Plant Loop Volume {m3} Water Heater Use Loop Inlet Node, !- Plant Side Inlet Node Name Water Heater Use Loop Outlet Node, !- Plant Side Outlet Node Name Water Heater Use Branches, !- Plant Side Branch List Name Water Heater Use Connectors, !- Plant Side Connector List Name Demand Inlet Node, !- Demand Side Inlet Node Name Demand Outlet Node, !- Demand Side Outlet Node Name Demand Branches, !- Demand Side Branch List Name Demand Connectors, !- Demand Side Connector List Name OPTIMAL; !- Load Distribution Scheme PlantEquipmentOperationSchemes, DHW Loop Operation, !- Name PlantEquipmentOperation:HeatingLoad, !- Control Scheme 1 Object Type DHW Control Scheme, !- Control Scheme 1 Name Always On; !- Control Scheme 1 Schedule Name PlantEquipmentOperation:HeatingLoad, DHW Control Scheme, !- Name 0, !- Load Range 1 Lower Limit {W} 10000000, !- Load Range 1 Upper Limit {W} DHW Plant Equipment; !- Range 1 Equipment List Name PlantEquipmentList, DHW Plant Equipment, !- Name WaterHeater:Mixed, !- Equipment 1 Object Type Water Heater; !- Equipment 1 Name SetpointManager:Scheduled, DHW Loop Set Point Manager, !- Name Temperature, !- Control Variable Hot Water Set Point Temp Schedule, !- Schedule Name Water Heater Use Loop Outlet Node; !- Setpoint Node or NodeList Name !***PLANT DHW LOOP: WATER HEATER SIDE*** BranchList, Water Heater Use Branches, !- Name Water Heater Use Inlet Branch, !- Branch 1 Name Water Heater Use Branch, !- Branch 2 Name Water Heater Use Outlet Branch; !- Branch 3 Name ConnectorList, Water Heater Use Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type Water Heater Use Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type Water Heater Use Mixer; !- Connector 2 Name Connector:Splitter, Water Heater Use Splitter, !- Name Water Heater Use Inlet Branch, !- Inlet Branch Name Water Heater Use Branch; !- Outlet Branch 1 Name Connector:Mixer, Water Heater Use Mixer, !- Name Water Heater Use Outlet Branch, !- Outlet Branch Name Water Heater Use Branch; !- Inlet Branch 1 Name Branch, Water Heater Use Inlet Branch, !- Name , !- Pressure Drop Curve Name Pump:VariableSpeed, !- Component 1 Object Type DHW Pump, !- Component 1 Name Water Heater Use Loop Inlet Node, !- Component 1 Inlet Node Name DHW Pump Outlet Node; !- Component 1 Outlet Node Name ! No pumping energy; water mains pressure only Pump:VariableSpeed, DHW Pump, !- Name Water Heater Use Loop Inlet Node, !- Inlet Node Name DHW Pump Outlet Node, !- Outlet Node Name AUTOSIZE, !- Design Maximum Flow Rate {m3/s} 0, !- Design Pump Head {Pa} AUTOSIZE, !- Design Power Consumption {W} 1.0, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream 0, !- Coefficient 1 of the Part Load Performance Curve 1, !- Coefficient 2 of the Part Load Performance Curve 0, !- Coefficient 3 of the Part Load Performance Curve 0, !- Coefficient 4 of the Part Load Performance Curve 0, !- Design Minimum Flow Rate {m3/s} INTERMITTENT; !- Pump Control Type Branch, Water Heater Use Branch, !- Name , !- Pressure Drop Curve Name WaterHeater:Mixed, !- Component 1 Object Type Water Heater, !- Component 1 Name Water Heater Use Inlet Node, !- Component 1 Inlet Node Name Water Heater Use Outlet Node; !- Component 1 Outlet Node Name Branch, Water Heater Use Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Water Heater Use Outlet Pipe, !- Component 1 Name Water Heater Use Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name Water Heater Use Loop Outlet Node; !- Component 1 Outlet Node Name Pipe:Adiabatic, Water Heater Use Outlet Pipe, !- Name Water Heater Use Outlet Pipe Inlet Node, !- Inlet Node Name Water Heater Use Loop Outlet Node; !- Outlet Node Name !***PLANT DHW LOOP: DOMESTIC HOT WATER SIDE*** BranchList, Demand Branches, !- Name Demand Inlet Branch, !- Branch 1 Name Domestic Hot Water Branch, !- Branch 2 Name Demand Outlet Branch; !- Branch 3 Name ConnectorList, Demand Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type Demand Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type Demand Mixer; !- Connector 2 Name Connector:Splitter, Demand Splitter, !- Name Demand Inlet Branch, !- Inlet Branch Name Domestic Hot Water Branch; !- Outlet Branch 1 Name Connector:Mixer, Demand Mixer, !- Name Demand Outlet Branch, !- Outlet Branch Name Domestic Hot Water Branch; !- Inlet Branch 1 Name Branch, Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Demand Inlet Pipe, !- Component 1 Name Demand Inlet Node, !- Component 1 Inlet Node Name Demand Pipe-DHW Node; !- Component 1 Outlet Node Name Pipe:Adiabatic, Demand Inlet Pipe, !- Name Demand Inlet Node, !- Inlet Node Name Demand Pipe-DHW Node; !- Outlet Node Name Branch, Domestic Hot Water Branch, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type Domestic Hot Water, !- Component 1 Name Domestic Hot Water Inlet Node, !- Component 1 Inlet Node Name Domestic Hot Water Outlet Node; !- Component 1 Outlet Node Name WaterUse:Connections, Domestic Hot Water, !- Name Domestic Hot Water Inlet Node, !- Inlet Node Name Domestic Hot Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name NONE, !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} demanda_acs; !- Water Use Equipment 1 Name Branch, Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Demand Outlet Pipe, !- Component 1 Name Demand DHW-Pipe Node, !- Component 1 Inlet Node Name Demand Outlet Node; !- Component 1 Outlet Node Name Pipe:Adiabatic, Demand Outlet Pipe, !- Name Demand DHW-Pipe Node, !- Inlet Node Name Demand Outlet Node; !- Outlet Node Name Output:VariableDictionary,Regular; OutputControl:Table:Style, HTML; !- Column Separator Output:Table:SummaryReports, AllSummary; !- Report 1 Name Output:Variable,*,Water Heater Electric Consumption Rate [W],Hourly,Always On; Output:Variable,*,Water Heater Electric Consumption [J],Monthly,Always On; Output:Variable,*,Water Heater Electric Consumption [J],Annual,Always On; Output:Variable,*,Water Heater Gas Consumption Rate [W],Hourly,Always On; Output:Variable,*,Water Heater Gas Consumption [J],Monthly,Always On; Output:Variable,*,Water Heater Gas Consumption [J],Annual,Always On; Output:Variable,*,Water Mains Temperature,Hourly,Always On; Output:Variable,*,Water Heater Tank Temperature,Hourly,Always On;