Materials: [ Cód.: sau25testcontrollersb.mlx ] [ PDF ]
This video simulates the pen-and-paper control design carried out in videos [
In here, we discuss the Matlab code to generate the closed-loop dynamics and we simulate it with three controllers, all of them assigning the setpoint poles at to fulfill the settling time specification. The three controllers are:
Proportional controller, which does not fulfill the required zero error static specificacion, so it was deemed invalid in the referred examination.
PI controller using the cancellation trick so that the plant pole was cancelled in the setpoint response (but a pinned pole appeared in the disturbance response), and only a single pole was assigned.
PI controller assigning two closed-loop poles at , no cancellation involved.
The second and third options were valid in said examination. Here, we plot their closed-loop time response (step response to both a setpoint step and a disturbance step) and their closed-loop frequency response (only amplitude Bode diagrams), and comment upon what can be concluded from said plots.
Note that closed-loop frequency response analysis isn’t that common in a first
undergraduate control course and, indeed, it was not taught in my course.
Nevertheless, for a more advanced student, it is indeed advisable that you watch
through the frequency-response analysis in the second half of the video.
You might wish to review the basic definitions of closed-loop frequency
response concepts in video [
*Link to my [ whole collection] of videos in English. Link to larger [ Colección completa] in Spanish.